archive-mobi.com » MOBI » C » CONTRIVE.MOBI

Total: 330

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Installation
    guaranteed raised to IP54 for open air application A B C D E F X S Analog and digital input terminals 12 x 2 5mm2 AWG14 Output green LED indicators GSM operation blue LED indicator OFF No power supply ON Module switched ON Not registered on the network missing SIM or invalid PIN SLOW FLASH 200ms ON 2s OFF Module switched ON Registered on the network QUICK FLASH 200ms ON

    Original URL path: http://www.contrive.mobi/mobicontrol/en/Installation.html (2015-09-07)
    Open archived version from archive


  • Battery
    sides of front cover to release it Pull the front cover and keep it in a safe place Plug unplug battery connector from the socket K Replace the front cover to close the unit Disconnect the battery if the device is put out of service Before a long period of inactivity switch off the unit to prevent deep discharge of the battery This operation can be accomplished using Mobi Suite

    Original URL path: http://www.contrive.mobi/mobicontrol/en/Battery.html (2015-09-07)
    Open archived version from archive

  • Digital Inputs
    Input supply voltage 3 3 Vdc at terminal 04 If switches are supplied by an external power supply negative terminal must be connected to terminal 01 A zener diode can provide an easy solution to keep input voltage in the 9Vdc range The following figure shows some possible wiring diagram Inputs 1 and 2 uses the internal 3 3 Vdc power supply Inputs 3 and 4 uses an external 5

    Original URL path: http://www.contrive.mobi/mobicontrol/en/DigitalInputs.html (2015-09-07)
    Open archived version from archive

  • Mobi.Suite_EN

    (No additional info available in detailed archive for this subpage)
    Original URL path: /mobisuite/en/ (2015-09-07)


  • Installation
    degree IP40 must be guaranteed raised to IP54 for open air application A B C E F X S Analog input terminals 12 x 2 5mm2 AWG14 Output green LED indicators GSM operation blue LED indicator OFF No power supply ON Module switched ON Not registered on the network missing SIM or invalid PIN SLOW FLASH 200ms ON 2s OFF Module switched ON Registered on the network QUICK FLASH 200ms

    Original URL path: http://www.contrive.mobi/mobiswitch/en/Installation.html (2015-09-07)
    Open archived version from archive

  • SIM card
    card use it and read the information inside You may protect the SIM card later using Mobi Suite configuration software Disconnect all power supplies and battery before to insert or remove the SIM card Replace the plastic cover before to operate the unit SIM card holder 3V and 1 8V SIM card allowed If you insert a SIM card that asks for a PIN number different from that stored into

    Original URL path: http://www.contrive.mobi/mobiswitch/en/SIMcard.html (2015-09-07)
    Open archived version from archive

  • Power Supply
    20 The power supply must not be shared with other equipment suggested power supply source is a simple 12V AC 10VA transformer Supply voltage 9 5 27 V AC 9 5 35 V DC Power consumption 5 W peak 200 mW idle Screw connector 2 x 2 5 mm 2 AWG14 An automatic 2 pole circuit breaker or equivalent protection capable of disconnecting circuit in the event of short circuit

    Original URL path: http://www.contrive.mobi/mobiswitch/en/PowerSupply.html (2015-09-07)
    Open archived version from archive

  • USB supply
    keep the unit alive if capable of sourcing 500 mA peak current Any wall or vehicle adapter providing 5V DC can be used The unit can receive power supply both from terminal connector and RJ plug at same time Supply

    Original URL path: http://www.contrive.mobi/mobiswitch/en/USBsupply.html (2015-09-07)
    Open archived version from archive



  •