archive-mobi.com » MOBI » C » CONTRIVE.MOBI

Total: 330

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Solar Panel
    The power supply provided by this photovoltaic unit is enough to keep the internal battery charged and the unit working for most of application The unit can receive power supply both from terminal connector and RJ plug at same time RJ45 connection for other purposes can be restored using our special splitter 2505 00 08 USE ONLY ORIGINAL ACCESSORIES 2506 00 00 Mobi PV Dimension 200 x 120 x 30

    Original URL path: http://www.contrive.mobi/mobiswitch/en/SolarPanel.html (2015-09-07)
    Open archived version from archive


  • Battery
    command AT CPOF Battery should be disconnected only when the device is put out of service for very long time This operation should be made by qualified personnel only Disconnect all the wires from the terminal boards disconnect the antenna Remove the bottom cover to access the inside and keep it in a safe place Unplug battery connector from the socket K located on top side of the circuit Replace

    Original URL path: http://www.contrive.mobi/mobiswitch/en/Battery.html (2015-09-07)
    Open archived version from archive

  • Antenna
    880 to 915 MHz 1710 to 1785 MHz 1850 to 1910 MHz Frequency RX 869 to 894 MHz 925 to 960 MHz 1805 to 1880 MHz 1930 to 1990 MHz Impedance 50 ohm VSWR RXmax 1 5 1 TXmax 1 5 1 Polarization Linear Typical Gain 0 dBi in one direction at least The gain must not exceed 8 4dBi 850MHz and 3 5dBi 1900MHz We recommend a VSWR max

    Original URL path: http://www.contrive.mobi/mobiswitch/en/Antenna.html (2015-09-07)
    Open archived version from archive

  • Wiring
    1 Analog Input 2 03 15 Relay Output 2 Positive 3 3 Vdc 04 16 17 Digital Counter Input 1 18 Digital Counter Input 2 19 Power Supply 20 Power Supply A regulated 3 3Vdc 50mA max is available at screw terminal 04 respect to terminal 01 If battery is equipped this power supply is provided also when main power supply is missing To prevent permanent damage to battery external

    Original URL path: http://www.contrive.mobi/mobiswitch/en/Wiring.html (2015-09-07)
    Open archived version from archive

  • Digital / Counter Inputs
    seconds Inputs can operate also as a pulse or time counter SPST contacts magnetic reed or hall sensor and electronic switches can be used Internal power supply is available at terminal 04 using electronic switches this is the positive leg Input voltage range 3 9 Vdc Input current 5mA 5V Debounce time 1 300 seconds Pulse width 200 ms 20 ms configurable Frequency 2 5 Hz Input supply voltage 3

    Original URL path: http://www.contrive.mobi/mobiswitch/en/DigitalCounterInputs.html (2015-09-07)
    Open archived version from archive

  • Analog Inputs
    01 V Accuracy 1 Impedance 25 Kohm Input range 0 20 mA Resolution 0 02 mA Accuracy 1 Impedance 100 ohm An NTC temperature sensor measuring in the range 10 to 60 C can be directly connected to analog inputs Set the dip switches as shown in figure to enable NTC software linearization For long lines use shielded cable the shield must be connected at terminal 01 only Input range

    Original URL path: http://www.contrive.mobi/mobiswitch/en/AnalogInputs1.html (2015-09-07)
    Open archived version from archive

  • Outputs
    green LED Common return is screw terminal 13 Nominal current 3 A Nominal voltage 250 Vac Breaking voltage 277 Vac Max breaking capacity 750 VA Minimum contact load 1 mA 5 Vdc cadmium free contacts Insulation to IEC60664 Voltage rating 277 Vac Pollution degree 2 Category as basic insulation III Category as reinforced insulation II Surge voltage coil contacts 5000 Vrms Dielectric strenght 3000 Vrms coil contacts 750 Vrms open

    Original URL path: http://www.contrive.mobi/mobiswitch/en/Outputs.html (2015-09-07)
    Open archived version from archive

  • Care & Maintenance
    the unit in dusty or dirty areas Do not use chemical cleaning agent on the unit or the SIM card Do not attempt to disassemble the unit or remove any part or label Do not expose the unit to water rain or spilt beverages It is not waterproof Do not abuse the unit by dropping knocking or violenty shaking it Rough handling can damage it Do not place the unit alongside computer discs credit or travel cards or other magnetic media The information contained on these devices may be affected This unit is under your responsibility Please treat it with care respecting all local regulations It is not a toy keep it in a safe place and out of the reach of children Treat the SIM card with the same care as your credit card do not bend or scratch or expose it to static electricity Keep your unlock and PIN codes in safe place Both fixed and mobile applications are allowed as defined below Fixed means that the device is physically secured at one location and is not able to be easily moved to another location Mobile means that the device is designed to be used in other than

    Original URL path: http://www.contrive.mobi/mobiswitch/en/CareMaintenance.html (2015-09-07)
    Open archived version from archive



  •