archive-mobi.com » MOBI » C » CONTRIVE.MOBI

Total: 330

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • Configuration
    the SIM card Phonebook DELETE USERS BY NAME DEL grp name grp S SIM card phonebook Users Group 1 U ME phonebook Users Group 2 R ME phonebook Recipient name name of users to be removed DEL S John Doe delete all users John Doe from User Group 1 DELETE USERS BY PHONE NUMBER DEL grp phn grp S SIM card phonebook Users Group 1 U ME phonebook Users Group 2 R ME phonebook Recipient phn phone number of users to be removed DEL R 39333333 delete all users whose phone number is 39333333 from Recipients FOLLOWING EDIT COMMANDS ARE REPORTED FOR DOCUMENTATION PURPOSE IT S STRONGLY SUGGESTED TO USE MOBI SUITE OR WEB CONFIGURATOR ADD USERS GROUP 1 ADD grp name phn grp S group of USER1 name User s name up to 14 alphanumeric characters phn User s phone number up to 80 characters 0 9 ADD USERS GROUP 2 ADD grp name phn tick imt strt ims expr ime mail twt grp U group of USER2 name User s name up to 30 alphanumeric characters phn User s phone number up to 80 characters 0 9 tick 0 999 allowed operations imt 1 9 interactive message associated

    Original URL path: http://www.contrive.mobi/mobiswitch/en/Configuration1.html (2015-09-07)
    Open archived version from archive


  • Users
    phone number found into the SIM card will be considered belonging to authorized users This group of users can be enabled or disabled at any time by means of remote or local commands A very simple solution to add modify or delete SIM card USERS is by using a mobile phone following instructions provided by phone manufacturer insert the SIM card into the SIM cardholder turn on the phone scroll the option menu to enter the SIM card phonebook edit mode enter the users name and telephone number using international format Insert the SIM card into the device SIM Holder and turn on the power supply ME USERS GROUP 2 Up to 400 users can be stored into Mobi Switch Phonebook Mobile Equipment Users Any phone number found will be considered belonging to authorized users This group of users can be enabled or disabled at any time by means of remote or local command Outputs can be controlled from any LANDLINE OR MOBILE telephone In order to be recognized as a registered user the user must verify that the presentation of his telephone number CLIP is enabled The unit will not answer to unrecognized phone number calls WILDCARD CHARACTER Star

    Original URL path: http://www.contrive.mobi/mobiswitch/en/Users.html (2015-09-07)
    Open archived version from archive

  • Call Control (CLIP)
    OUTPUTS ACTIVATION TIME An incoming DATA call from registered users will activate OUTPUT 2 for the specified OUTPUTS ACTIVATION TIME The incoming call is terminated immediately no answer This is the factory default setting OUTPUTS ACTIVATION TIME is the time an output remains active after a recognized phone call Range 1 300 seconds factory default 3 seconds TOGGLE An incoming VOICE and FAX call toggles OUTPUT 1 on to off and vice versa An incoming DATA call toggles OUTPUT 2 on to off and vice versa If the user remains online Mobi Switch will answer the call and confirm the operation REVERSE This mode involves both outputs Any incoming call from registered users starts a sequence 1 output 1 activated for the time set in OUTPUT 1 ACTIVATION TIME P interval for the time set in PAUSE TIME 2 output 2 activated for the time set in OUTPUT 2 ACTIVATION TIME The incoming call is terminated immediately no answer ANSWER Mobi Switch answers to incoming call from registered users and waits for commands issued by means of phone keypad DTMF Default commands assigned to phone keypad could be modified 1 OUT 1 ON 2 OUT 2 ON 3 OUT 1

    Original URL path: http://www.contrive.mobi/mobiswitch/en/CallControlCLIP.html (2015-09-07)
    Open archived version from archive

  • Shortcut Commands
    complete the remaining time Optional trailer text ddMMyyhhmm to set output ON until given date and time dd 00 to 31 day MM 00 to 12 month yy 00 to 99 year hh 00 to 23 hours mm 00 to 59 minutes If a blackout occur and the output has been set RETENTIVE Mobi Switch will turn ON again until the specified date If the date has been elapsed the output will not be turned ON S2 Set output 2 permanently ON Optional trailer text hhmmss to set output ON until specified time has been elapsed hh 00 to 23 hours mm 00 to 59 minutes ss 00 to 59 seconds If a power fail occur and the output has been set RETENTIVE Mobi Switch will complete the remaining time Optional trailer text ddMMyyhhmm to set output ON until given date and time dd 00 to 31 day MM 00 to 12 month yy 00 to 99 year hh 00 to 23 hours mm 00 to 59 minutes If a blackout occur and the output has been set RETENTIVE Mobi Switch will turn ON again until the specified date If the date has been elapsed the output will not be

    Original URL path: http://www.contrive.mobi/mobiswitch/en/ShortcutCommands.html (2015-09-07)
    Open archived version from archive

  • Send to Console
    When the first character of a message is an exclamation point all the trailing text will be sent to to local COM port It s the easiest way to send an alphanumeric string to an external device Send text string

    Original URL path: http://www.contrive.mobi/mobiswitch/en/SendtoConsole.html (2015-09-07)
    Open archived version from archive

  • Messages
    Messages Mobi Switch can send many different messages following specific request or local event Copyright 2013 by Contrive All Rights Reserved

    Original URL path: http://www.contrive.mobi/mobiswitch/en/Messages.html (2015-09-07)
    Open archived version from archive

  • Status
    OUTPUT 1 O1 on 13 09 2013 18 30 OUTPUT 2 O2 on 00 00 09 POWER SUPPLY main OK BATTERY batt 80 TEMPERATURE temp 23 C CALL call pulse USERS GROUP 1 ENABLE usr1 on USERD GROUP 2 ENABLE usr2 off IDENTIFIER Short text reporting the identifier assigned to Mobi Switch Settings Device Mobi Switch DIGITAL INPUT C1 C2 Status of additional digital inputs 0 input is open inactive 1 input is closed active TIME COUNTER INPUT T1 T2 Accumulated time input closed active followed by min minutes 350 min PULSE COUNTER INPUT P1 P2 Accumulated counts followed by measuring unit current ratio measured during last minute followed by measuring unit min 11560 W 12 W min ANALOG INPUT A1 A2 Returns current reading mean over 4 sec followed by measuring unit 48 65 V Temperature measured by external sensor is reported when the channel has been set as NTC Value and measuring unit according to channel setting C F 14 C SETPOINT S1 S2 Current setpoint used to control outputs based on analog input measurement Nothing is returned when setpoint 0 disabled The safety limit value may follow not returned when set to zero 20 4 typical ambient temperature regulation setpoint 20 antifrost 4 assuming input channel has been set to C OUTPUTS O1 O2 Status of outputs off output is released inactive on output is active remaining time may follow when output has been activated using timer option 9 minutes remaining on 00 00 09 release date may follow when output has been activated with expiration date will be turned off April 25 2013 at noon on 25 04 13 12 00 00 remaining time and symbol will follow when the output has been activated by clip command activated by clip will be released within 15 seconds

    Original URL path: http://www.contrive.mobi/mobiswitch/en/Status.html (2015-09-07)
    Open archived version from archive

  • Alert
    will be sent to this destination number Up to 50 characters are available for message text specific for each Recipient EXTENDED SMS Same as a normal SMS but a status message will be included EMAIL When selected event occurs an email message will be sent to this destination address The sender name is the IDENTIFIER assigned to Mobi Switch The sender email address is the EMAIL ADDRESS assigned to Mobi

    Original URL path: http://www.contrive.mobi/mobiswitch/en/Alert.html (2015-09-07)
    Open archived version from archive



  •