archive-mobi.com » MOBI » C » CONTRIVE.MOBI

Total: 330

Choose link from "Titles, links and description words view":

Or switch to "Titles and links view".
  • SIM card
    card use it and read the information inside You may protect the SIM card later using Mobi Suite configuration software Disconnect all power supplies and battery before to insert or remove the SIM card Replace the plastic cover before to operate the unit SIM card holder 3V and 1 8V SIM card allowed If you insert a SIM card that asks for a PIN number different from that stored into

    Original URL path: http://www.contrive.mobi/mobicontrol/en/SIMcard.html (2015-09-07)
    Open archived version from archive


  • Power Supply
    20 The power supply must not be shared with other equipment suggested power supply source is a simple 12V AC 10VA transformer Supply voltage 9 5 27 V AC 9 5 35 V DC Power consumption 5 W peak 200 mW idle Screw connector 2 x 2 5 mm 2 AWG14 An automatic 2 pole circuit breaker or equivalent protection capable of disconnecting circuit in the event of short circuit

    Original URL path: http://www.contrive.mobi/mobicontrol/en/PowerSupply.html (2015-09-07)
    Open archived version from archive

  • USB supply
    keep the unit alive if capable of sourcing 500 mA peak current Any wall or vehicle adapter providing 5V DC can be used The unit can receive power supply both from terminal connector and RJ plug at same time Supply

    Original URL path: http://www.contrive.mobi/mobicontrol/en/USBsupply.html (2015-09-07)
    Open archived version from archive

  • Solar Panel
    power supply provided by this photovoltaic unit is enough to keep the internal battery charged and the unit working for most of application The unit can receive power supply both from terminal connector and RJ plug at same time RJ45 connection for other purposes can be restored using our special splitter 2505 00 08 USE ONLY ORIGINAL ACCESSORIES 2506 00 00 Mobi PV Dimension 200 x 120 x 30 mm

    Original URL path: http://www.contrive.mobi/mobicontrol/en/SolarPanel.html (2015-09-07)
    Open archived version from archive

  • Counter Inputs
    indication Independent activation debounce time can be set in range of 1 to 300 seconds Inputs can operate also as a pulse or time counter SPST contacts magnetic reed hall sensor or electronic switches can be used Pulse width configurable for mechanical 200ms or electronic 20ms sensor Input voltage range 3 9 Vdc Input current 5mA 5V Debounce time 1 300 seconds Pulse width 200 ms 20 ms configurable Frequency

    Original URL path: http://www.contrive.mobi/mobicontrol/en/CounterInputs.html (2015-09-07)
    Open archived version from archive

  • Analog Inputs
    01 V Accuracy 1 Impedance 25 Kohm Input range 0 20 mA Resolution 0 02 mA Accuracy 1 Impedance 100 ohm An NTC temperature sensor measuring in the range 10 to 60 C can be directly connected to analog inputs Set the dip switches as shown in figure to enable NTC software linearization For long lines use shielded cable the shield must be connected at terminal 01 only Input range

    Original URL path: http://www.contrive.mobi/mobicontrol/en/AnalogInputs.html (2015-09-07)
    Open archived version from archive

  • Outputs
    green LED Common return is screw terminal 13 Nominal current 3 A Nominal voltage 250 Vac Breaking voltage 277 Vac Max breaking capacity 750 VA Minimum contact load 1 mA 5 Vdc cadmium free contacts Insulation to IEC60664 Voltage rating 277 Vac Pollution degree 2 Category as basic insulation III Category as reinforced insulation II Surge voltage coil contacts 5000 Vrms Dielectric strenght 3000 Vrms coil contacts 750 Vrms open

    Original URL path: http://www.contrive.mobi/mobicontrol/en/Outputs.html (2015-09-07)
    Open archived version from archive

  • Care & Maintenance
    the unit in dusty or dirty areas Do not use chemical cleaning agent on the unit or the SIM card Do not attempt to disassemble the unit or remove any part or label Do not expose the unit to water rain or spilt beverages It is not waterproof Do not abuse the unit by dropping knocking or violenty shaking it Rough handling can damage it Do not place the unit alongside computer discs credit or travel cards or other magnetic media The information contained on these devices may be affected This unit is under your responsibility Please treat it with care respecting all local regulations It is not a toy keep it in a safe place and out of the reach of children Treat the SIM card with the same care as your credit card do not bend or scratch or expose it to static electricity Keep your unlock and PIN codes in safe place Both fixed and mobile applications are allowed as defined below Fixed means that the device is physically secured at one location and is not able to be easily moved to another location Mobile means that the device is designed to be used in other than

    Original URL path: http://www.contrive.mobi/mobicontrol/en/CareMaintenance.html (2015-09-07)
    Open archived version from archive



  •