    name domain com status will be included into email body AT EMAIL name domain com Message text 0 send email to name domain com only Subject line AT EMAIL name domain com switch i6 motor O1 send email to name domain com with text comprising some dynamic variables EMAIL LOG FILE AT LOGEMAIL dest dest destination email address AT LOGEMAIL name domain com send last 98 events stored into LOG memory to name domain com LOCATION AT WAY dest dest international phone number or 1 last voice caller 2 last data caller 3 last SMS sender 5 console Omitting destination status will be returned on the same bearer used for the command Web services must be enabled AT WAY return geographic address nearest to main GSM cell AT WAY 39444444 send geographic address nearest to main GSM cell to 39444444 AT WAY 1 send geographic address nearest to main GSM cell to last voice caller LIST CALLS AT LIST type dest type A answered calls U unanswered calls dest international phone number or 1 last voice caller 2 last data caller 3 last SMS sender 5 console Omitting destination list will be returned on the same bearer used for the command AT LISTU return last incoming calls terminated without answer AT LISTA 39444444 send last answered incoming calls to 39444444 AT LISTA 1 send last answered incoming calls to last voice caller ENable ALERTS to recipients AT ALERT name name recipient name to enable the alert Omitting recipient field alerts will be sent to all recipients disable ALERTS to recipients AT NOALERT name name recipient name to disable the alert Omitting recipient field alerts will be stop to all recipients At start up all recipients are enabled to receive alerts AT ALERT an enable recipient name starting with an e

    Original URL path: http://www.contrive.mobi/mobicontrol/en/Messaging.html (2015-09-07)
    Open archived version from archive


  • Audio
    audio message associated to Input I3 closing 105 play audio message associated to Input I4 closing 106 play audio message associated to Input I5 closing 107 play audio message associated to Input I6 closing 108 play audio message associated to Input I7 closing 109 play audio message associated to Input I8 closing 110 play audio message associated to Power Supply Restore 111 play audio message associated to Input I1 opening 112 play audio message associated to Input I2 opening 113 play audio message associated to Input I3 opening 114 play audio message associated to Input I4 opening 115 play audio message associated to Input I5 opening 116 play audio message associated to Input I6 opening 117 play audio message associated to Input I7 opening 118 play audio message associated to Input I8 opening 119 play audio message associated to Counter C1 closing 120 play audio message associated to Counter C2 closing 121 play audio message associated to Counter C1 opening 122 play audio message associated to Counter C2 opening 123 play audio message associated to Pulse Counter P1 Low Ratio 124 play audio message associated to Pulse Counter P2 Low Ratio 125 play audio message associated to Pulse Counter P1 Hi Ratio 126 play audio message associated to Pulse Counter P2 Hi Ratio 127 play audio message associated to Time Counter T1 Threshold 128 play audio message associated to Time Counter T2 Threshold 129 play audio message associated to Pulse Counter P1 Threshold 130 play audio message associated to Pulse Counter P2 Threshold 131 play audio message associated to Low Battery 132 play audio message associated to ADC1 Below Threshold 133 play audio message associated to ADC2 Below Threshold 134 play audio message associated to Low Internal Temperature 135 play audio message associated to High Battery 136 play audio message

    Original URL path: http://www.contrive.mobi/mobicontrol/en/Audio.html (2015-09-07)
    Open archived version from archive

  • Configuration
    force device to perform a data connection and download the complete configuration file from the Web PHONEBOOK SIZE AT SIZE phbk phbk S SIM card phonebook Users Group 1 U ME phonebook Users Group 2 R ME phonebook Recipient AT SIZE S return the number of available entries in the SIM card Phonebook DELETE USERS BY NAME AT DEL grp name grp S SIM card phonebook Users Group 1 U ME phonebook Users Group 2 R ME phonebook Recipient name name of users to be removed AT DEL S John Doe delete all users John Doe from User Group 1 DELETE USERS BY PHONE NUMBER AT DEL grp phn grp S SIM card phonebook Users Group 1 U ME phonebook Users Group 2 R ME phonebook Recipient phn phone number of users to be removed AT DEL R 39333333 delete all users whose phone number is 39333333 from Recipients Search limited to main phone number primary call only FOLLOWING EDIT COMMANDS ARE REPORTED FOR DOCUMENTATION PURPOSE IT S STRONGLY SUGGESTED TO USE MOBI SUITE OR WEB CONFIGURATOR ADD USERS GROUP 1 AT ADD grp name phn grp S group of USER1 name User s name up to 14 alphanumeric characters phn User s phone number up to 80 characters 0 9 ADD USERS GROUP 2 AT ADD grp name phn tick imt strt ims expr ime mail twt grp U group of USER2 name User s name up to 30 alphanumeric characters phn User s phone number up to 80 characters 0 9 tick 0 999 allowed operations imt 1 9 interactive message associated with tickets strt DDMMYYhhmm start date ims 1 9 interactive message associated with start expr DDMMYYhhmm expiry date ime 1 9 interactive message associated with expiry mail User s email address up to 50 alphanumeric characters

    Original URL path: http://www.contrive.mobi/mobicontrol/en/Configuration.html (2015-09-07)
    Open archived version from archive

  • Control
    I1 I2 digital input I2 I3 digital input I3 I4 digital input I4 I5 digital input I5 I6 digital input I6 I7 digital input I7 I8 digital input I8 C1 digital input C1 C2 digital input C2 mode 0 simulate opening 1 simulate closing INI1 return current status for input I1 INC1 1 simulate digital input C1 activation close all associated events and alerts will be served INI8 0 simulate digital input I8 release open all associated events and alerts will be served RETURN current value for analog inputs ANA ch dest ch 1 analog input 1 2 analog input 2 dest international phone number or 1 last voice caller 2 last data caller 3 last SMS sender 5 console Return current value and unit of measure of the analog input channel selected Omitting destination the information will be returned on the same bearer Measure unavailable returns Reading open NTC returns EEE reading short circuited NTC returns ANA1 44123456789 send to number 44123456789 the current value and unit of measure for analog input A1 ANA2 3 send to the last SMS sender the current value and unit of measure for analog input A2 simulate an incoming call CLIP type num type 1 voice fax call 2 data call num number of a user in Group 1 or Group 2 CLIP 1 simulate a voice call activity configured for output 1 will be deployed CLIP 2 440123456789 simulate a data call activity configured for output 2 will be deployed if number 440123456789 is a user saved in Group 1 SIM card or Group 2 ME phonebook disable group STOP grp grp 1 User Group 1 2 User Group 2 ENable group START grp grp 1 User Group 1 2 User Group 2 STOP1 disable group 1 reject all incoming calls from

    Original URL path: http://www.contrive.mobi/mobicontrol/en/Control1.html (2015-09-07)
    Open archived version from archive

  • Messaging
    list here body 0 do not include status into email body Email body will include a complete status if last parameter body is missing EMAIL name domain com Message text send email to name domain com status will be included into email body EMAIL name domain com Message text 0 send email to name domain com only Subject line EMAIL name domain com switch i6 motor O1 send email to name domain com with text comprising some dynamic variables EMAIL LOG FILE LOGEMAIL dest dest destination email address LOGEMAIL name domain com send last 98 events stored into LOG memory to name domain com LOCATION WAY dest dest international phone number or 1 last voice caller 2 last data caller 3 last SMS sender 5 console Omitting destination status will be returned on the same bearer used for the command Web services must be enabled WAY return geographic address nearest to main GSM cell WAY 39444444 send geographic address nearest to main GSM cell to 39444444 WAY 1 send geographic address nearest to main GSM cell to last voice caller LIST CALLS LIST type dest type A answered calls U unanswered calls dest international phone number or 1 last voice caller 2 last data caller 3 last SMS sender 5 console Omitting destination status will be returned on the same bearer used for the command LISTU return last incoming calls terminated without answer LISTA 39444444 send last answered incoming calls to 39444444 LISTA 1 send last answered incoming calls to last voice caller ENable ALERTS to recipients ALERT name name recipient name to enable the alert Omitting recipient field alerts will be sent to all recipients disable ALERTS to recipients NOALERT name name recipient name to disable the alert Omitting recipient field alerts will be stop to all recipients At

    Original URL path: http://www.contrive.mobi/mobicontrol/en/Messaging1.html (2015-09-07)
    Open archived version from archive

  • Audio
    3 closing 105 play audio message associated to Input 4 closing 106 play audio message associated to Input 5 closing 107 play audio message associated to Input 6 closing 108 play audio message associated to Input 7 closing 109 play audio message associated to Input 8 closing 110 play audio message associated to Power Supply Restore 111 play audio message associated to Input 1 opening 112 play audio message associated to Input 2 opening 113 play audio message associated to Input 3 opening 114 play audio message associated to Input 4 opening 115 play audio message associated to Input 5 opening 116 play audio message associated to Input 6 opening 117 play audio message associated to Input 7 opening 118 play audio message associated to Input 8 opening 119 play audio message associated to Counter 1 closing 120 play audio message associated to Counter 2 closing 121 play audio message associated to Counter 1 opening 122 play audio message associated to Counter 2 opening 123 play audio message associated to Pulse Counter 1 Low Ratio 124 play audio message associated to Pulse Counter 2 Low Ratio 125 play audio message associated to Pulse Counter 1 Hi Ratio 126 play audio message associated to Pulse Counter 2 Hi Ratio 127 play audio message associated to Time Counter 1 Threshold 128 play audio message associated to Time Counter 2 Threshold 129 play audio message associated to Pulse Counter 1 Threshold 130 play audio message associated to Pulse Counter 2 Threshold 131 play audio message associated to Low Battery 132 play audio message associated to ADC1 Below Threshold 133 play audio message associated to ADC2 Below Threshold 134 play audio message associated to Low Internal Temperature 135 play audio message associated to High Battery 136 play audio message associated to ADC1 Above Threshold

    Original URL path: http://www.contrive.mobi/mobicontrol/en/Audio1.html (2015-09-07)
    Open archived version from archive

  • Settings
    counts clear log file CLEARLOG CLEARLOG delete all entries internal event memory LOG set threshold THR id act val id A1 analog input 1 A2 analog input 2 P1 pulse input 1 ratio P2 pulse input 2 ratio act A rising above value B falling below value val 40 99999 set threshold value THRA1 B return current value for analog input 1 falling below threshold THRA1 B 80 set falling below threshold for analog input 1 to 80 THRA2 A 1200 set rising above threshold for analog input 2 to 1200 THRP1 B 9 set falling below threshold for ratio of pulse input 1 to 9 THRP2 A 3300 set rising above threshold for ratio of pulse input 2 to 3000 setpoint SET id value safe id 1 analog input 1 2 analog input 2 value ask for current setting 40 99999 setpoint value safe 40 99999 safe value Last parameter safe is optional and could be omitted SET1 return current settings for setpoint 1 SET1 20 set value of setpoint 1 to 20 safe parameter is omitted SET1 20 4 set value of setpoint 1 to 20 safe to 4 a typical setting for a room thermostat whose 20

    Original URL path: http://www.contrive.mobi/mobicontrol/en/Settings1.html (2015-09-07)
    Open archived version from archive

  • Configuration
    SIM card Phonebook SIZE S 2 250 DELETE USERS BY NAME DEL grp name grp S SIM card phonebook Users Group 1 U ME phonebook Users Group 2 R ME phonebook Recipient name name of users to be removed DEL S John Doe delete all users John Doe from User Group 1 DELETE USERS BY PHONE NUMBER DEL grp phn grp S SIM card phonebook Users Group 1 U ME phonebook Users Group 2 R ME phonebook Recipient phn phone number of users to be removed DEL R 39333333 delete all users whose phone number is 39333333 from Recipients FOLLOWING EDIT COMMANDS ARE REPORTED FOR DOCUMENTATION PURPOSE IT S STRONGLY SUGGESTED TO USE MOBI SUITE OR WEB CONFIGURATOR ADD USERS GROUP 1 ADD grp name phn grp S group of USER1 name User s name up to 14 alphanumeric characters phn User s phone number up to 80 characters 0 9 ADD USERS GROUP 2 ADD grp name phn tick imt strt ims expr ime mail twt grp U group of USER2 name User s name up to 30 alphanumeric characters phn User s phone number up to 80 characters 0 9 tick 0 999 allowed operations imt 1 9

    Original URL path: http://www.contrive.mobi/mobicontrol/en/Configuration1.html (2015-09-07)