  • Battery
    only the enabled channels NAME Assign a meaningful name to better identify the application Up to 20 characters available UNIT The unit of measurement used to report the battery level Not editable mV millivolts ACTIVATION TIME Minimum duration time to trigger the event Range 1 second to 17 hours 59 minutes 59 seconds Default 3 seconds LOW THRESHOLD FALLING BELOW Low battery detection threshold Range 3200 4800 mV The event

    Original URL path: http://www.contrive.mobi/mobisuite/en/Battery.html (2015-09-07)
    Open archived version from archive


  • Analog Inputs - A
    This text is reported within status SMS keep this text short as any measuring unit normally is HYSTERESIS Hysteresis applicable to threshold in the range 1 10 of full scale value Assuming 10V full scale hysteresis set to 1 is equivalent to 0 1V TOP Set the full scale value returned by device Range 1 99999 Assuming you have a temperature sensor output 0 10V equivalent to 0 100 C set the top value to 100 ZERO Optional offset to be used for measured value Range 0 90 Assuming the input range is 0 10V and you want to measure in the range 2 10V set 20 offset 10 0 2 2V ACTIVATION TIME Minimum duration time to trigger the event Range 1 second to 17 hours 59 minutes 59 seconds Default 3 seconds LOW THRESHOLD FALLING BELOW Low level threshold Range 1 99999 The event will be triggered for measured values falls below this value Select the optional local sound to be played HIGH THRESHOLD RISING ABOVE High level threshold Range 1 99999 The event will be triggered when measured values rises above this value Select the optional local sound to be played TEXT The text to be used

    Original URL path: http://www.contrive.mobi/mobisuite/en/AnalogInputsA.html (2015-09-07)
    Open archived version from archive

  • Example
    set to 5V H HIGH THRESHOLD HYSTERESIS i e 5V 0 1V 4 9V t ACTIVATION TIME set to 3 seconds 1 Event will be triggered when the input signal rises and remains above 5V for 3 seconds at least

    Original URL path: http://www.contrive.mobi/mobisuite/en/Example.html (2015-09-07)
    Open archived version from archive

  • Temperature
    only the enabled channels NAME Assign a meaningful name to better identify the application Up to 20 characters available UNIT The unit of measurement used to report the temperature Not editable C ACTIVATION TIME Minimum duration time to trigger the event Range 1 second to 17 hours 59 minutes 59 seconds Default 3 seconds LOW THRESHOLD FALLING BELOW Low temperature threshold Range 40 85 C The event will be triggered

    Original URL path: http://www.contrive.mobi/mobisuite/en/Temperature.html (2015-09-07)
    Open archived version from archive

  • Digital Inputs - C
    place Status message includes only the enabled channels NAME Assign a meaningful name to better identify the application Up to 20 characters available ACTIVATION TIME Minimum duration time to trigger the event Range 1 second to 17 hours 59 minutes 59 seconds Default 3 seconds ON OPEN The optional local sound to be played when the input is opening Select the sound from the drop down list If you want

    Original URL path: http://www.contrive.mobi/mobisuite/en/DigitalInputsC.html (2015-09-07)
    Open archived version from archive

  • Time Inputs - T
    FOR CURRENT ENTRY ENABLE DISABLE Disabling the channel all related events will not take place Status message includes only the enabled channels NAME Assign a meaningful name to better identify the application Up to 20 characters available ACTIVATION TIME Minimum duration time to start stop the time count Range 1 second to 17 hours 59 minutes 59 seconds Default 3 seconds ACCUMULATED TIME THRESHOLD The event will be triggered when

    Original URL path: http://www.contrive.mobi/mobisuite/en/TimeInputsT.html (2015-09-07)
    Open archived version from archive

  • Pulse Inputs - P
    switches PULSES CNT Set the number of pulses to increment the counter by 1 UNIT The measuring unit you want to display after the value Up to 10 characters available This text is reported within status SMS keep this text short as any measuring unit normally is UNDERFLOW THRESHOLD The event will be triggered when the measured flow falls below this value evaluated on 1 minute basis Range 0 3000

    Original URL path: http://www.contrive.mobi/mobisuite/en/PulseInputsP.html (2015-09-07)
    Open archived version from archive

  • Geofence
    NEW SETTINGS CONFIRM CONFIRM NEW SETTINGS FOR CURRENT ENTRY DETECT COUNTRY CHANGE The event will be triggered when the device is changing registration to a different Country network DETECT NETWORK CHANGE The event will be triggered when the device is changing registration to a different network operator DETECT AREA CHANGE The event will be triggered when the device is changing registration to a cellular area DETECT CELL CHANGE The event

    Original URL path: http://www.contrive.mobi/mobisuite/en/Geofence.html (2015-09-07)
    Open archived version from archive



  •